SurfaceShield Wipe Sampling Kit

The all-in-one kit for Hazardous Drug
Surface Wipe Sampling

SurfaceShield is a Hazardous Drug Surface Wipe Sampling kit designed to detect and quantify drug and chemical residue on surfaces in pharmacies, hospitals, and healthcare facilities. It supports USP <800> compliance, contamination monitoring, and cleaning verification.

 

SurfaceShield Wipe Sampling Kit

The all-in-one kit for Hazardous Drug Surface Wipe Sampling

SurfaceShield is a Hazardous Drug Surface Wipe Sampling kit designed to detect and quantify drug and chemical residue on surfaces in pharmacies, hospitals, and healthcare facilities. It supports USP <800> compliance, contamination monitoring, and cleaning verification.

Why Should You Test

Built Around USP 800 and NIOSH Guidance

USP <800> was developed to promote patient and employee safety from exposure to hazardous drugs in the healthcare setting across multiple activities including but not limited to, receipt, dispensing, compounding/manufacturing, administration, and disposal.

Also, NIOSH(National Institute for Occupational Safety and Health) recommends that employers develop a program to monitor the safety of employees working with hazardous drugs, By gathering baseline data, in addition to continuous monitoring, employers are able to assess the potential risk of exposure to hazardous drugs.

Why SurfaceShield?

SurfaceShield offers one of the simplest and most cost-effective ways to identify and quantify drug residue contamination on any surface, with a wipe sampling procedure designed for speed and accuracy. Each kit is customizable to the number of sample sets your facility needs, so you order only what your monitoring program requires.

SurfaceShield detects and measures hormones, chemotherapy agents, and hazardous and non-hazardous drugs on surfaces.

What’s Inside

Everything you need for compliant surface sampling

Base kit (2 sample sets)

  • 2 - Tubes
    x2
  • 2 -*Texwipe ® Swab
    x2
  • 2 - Single-use vials of sterile water
    x2
  • 2 - Pairs of gloves, re-closable bag
    x2
  • 10×10 cm (100 cm²) Template
    x1
  • 3 oz single-use cold pack
    x1
  • Instructions, blank labels, insulated mailer
    incl.

*Texwipe ® is a registered trademark of the Texwipe Company, LCC [Illinois Toll Works, Inc. (ITW)].

Features & Benefits

Customizable:

Kit can be customized according to the amount of sample sets required.

Proactive Risk Assessment:

Identify and quantify hazardous drug residue to better understand potential employee exposure and chemical cross-contamination risks. 

Cost-Effective Monitoring:

Targeted sampling means you pay only for what matters most.

Sampling Process

What & Where to sample

Identifying areas with high levels of surface contamination can provide valuable information to mitigate employee and patient risk, improve facility engineering controls, and implement revisions to your current work practices. 

◆   Receipt / Storage

Containers, storage floors, shelves, walls

◆   Compounding

Hood, adjacent surfaces, HD room surroundings, staging & weighing areas, mixing area (work surface, floors, walls), equipment, high-touch areas

◆   Dispensing

Counter-tops, keyboards, mouse, drug containers, hazardous drug vials or containers, pharmacy floor

◆   Administration

Preparation area, bedside equipment

◆   Transport

Carts

◆   Disposal

Shelves, waste containers, floors and walls

How It Works

Testing Made Simple

Order your kit

Order the all-in-one customizable sampling kit.

Swab the area

Properly swab the selected surface using the included template. 

Send to Eagle

We identify and quantify residue and report results in EagleTrax.

Learn About Our Testing Methods

Eagle Analytical is a recognized leader in pharmaceutical testing and USP <795>, USP <797> and USP <800> compliance.

Beyond The Kit

Testing Services

What you receive

The Kit

– Complete sampling supplies, ready to ship

– Insulated mailer for return shipping

– Step-by-step sampling instructions

What we do

The Service

– Identify and quantify residue with defensible data

– Detailed exposure reporting with clear concentrations

– Real-time tracking and trending in EagleTrax

– Continuously expanding analyte (API) coverage

SurfaceShield Video Guides

Frequently Asked Questions

Before you reach out

How do I return the sample?

Once the samples are properly collected and ready for shipping, they are placed and sealed inside the included insulated mailer. Complete the sample submission process in EagleTrax and mail the insulated mailer to Eagle for processing.  

If you have any questions about the packing or shipping process or need further assistance of any kind, please contact the Eagle Care Team at 800-745-8916. 

Where do I ship the samples to be tested?

Once you complete the sample submission process in EagleTrax, the shipping address will be provided on the sample submission form. 

How do I submit these samples for analysis?

 Click to view the Sample Submissions page which goes over the sample submission process. 

How do I collect the sample?

Each sampling kit includes a sample instruction card, as well as a QR code that provides access to step-by-step video instruction. 

What solvent should be used when sampling?

We recommend using the single-use vial of sterile water that is included in the kit but deionized or distilled water may be used. 

How often should I be testing?

USP <800> states: “Environmental wipe sampling for HD surface residue should be performed routinely (e.g., initially as a benchmark and at least every 6 months, or more often as needed, to verify containment).” 

How large of an area should I be swabbing per location?

The standard sampling area is 10 cm × 10 cm (4″ × 4″), but in some cases, the sampling area may be smaller, making the use of the provided template impractical. In these cases, swab the entire accessible surface area of the location and document the approximate area sampled. 

What if I do not see an HD that I would like to test?

Contact Client Care at 1-800-745-8916 ; the option of developing a method is possible.